Beijing Fuzhen Techn icalservice Co.,Ltd

Custom ization of non-standard equipm entforA ircom pressors, G asdryers, Nitrogen generators0 xygen generators
and Process gascom pressors

Product

Hotline: 18201366176
current location:Home > Product > Oxygen generator

Modular oxygen generator

views:

date:2024-12-19 14:37:58

Working principle of pressure swing adsorption (PSA) Oxygen Generator

The basic principle of pressure swing adsorption is to use adsorbents to have different adsorption capacities for adsorbates at different pressures, and to selectively adsorb various components of the separated gas mixture at a certain pressure. Under the selected adsorption conditions of the adsorbent, the impurity components in the feed gas are removed by pressurized adsorption, and these impurities are removed by depressurization to regenerate the adsorbent. Therefore, generally two adsorption towers are used, and the pressure of each adsorption tower combined by cyclic alternating transformation can achieve the purpose of continuous separation of gas mixtures. Because the adsorption and desorption processes are achieved through pressure changes, this process is called Pressure Swing Adsorption (PSA).

Core of PSA Oxygen production technology

The core of pressure swing adsorption oxygen production is oxygen producing molecular sieve. Under a certain pressure, it has strong adsorption ability for oxygen molecules, but poor adsorption ability for oxygen molecules. In this way, it can continuously adsorb oxygen molecules in the raw air during the process of continuous cycling and pressure changes, producing high-purity oxygen

Process flow of pressure swing adsorption Oxygen production

Fuzhentech Parameter table of Modular Oxygen Generator

Fuzhentech Parameter table of Modular Oxygen Generator

Model

FZ-MO-P02

FZ-MO-P04

FZ-MO-P06

FZ-MO-P08

FZ-MO-P10

FZ-MO-P12

Flow(m3/h

2.4

4.8

7.2

9.6

12

14.4

Flow(L/min

40

80

120

160

200

240

Pressure

3-5bar adjustable

1、The flow rate values in the table are obtained at ambient temperatures of 6.5 barg rated working pressure, ≤ 30 ℃ rated intake temperature, and 20 ℃;

2、The flow unit standard is based on a gas state of 20 ℃, 1013mbar (a), and 0% relative humidity;

3、Air intake index requirements ISO 8573-1:2010 [1:4:1]

4、Even if not notified in a timely manner, manufacturers have the right to modify existing parameters.

5、For other working conditions, please contact us directly for consultation